is the data transmission of the SC-Vector (RCB) with its 1.5 Gb/s rate which also guarantees a low return loss. Of course, the SC-Vector (RCB) can also serve as a high-quality G-SDI-video line for studio or OB van applications. With its dual shielding and outstanding damping values it offers numerous benefits compared to simple video cables. In comparison to a 0.6/3.7 video cable it allows up to 30 % longer transmission distances.
The SC-Vector (RCB) is used in OB vans, digital TV, at sporting events, live shows or other large events.
Advantages:
- Low damping values for long distances
- Robust and durable outer sleeve
Application:
- Digital SDI/HD-SDI long distance transmission
- Video transmission for OB van technology
Key Features
- Low damping values for long distances
- Robust and durable outer sleeve
Cable Properties
| Article number: | 600-0162 | 
| Name: | SC-Vector (RCB) | 
| EAN: | 4049371001359 | 
| Properties: | 3G-SDI, 6G-SDI, Analog, Digital 75 Ω, OFC oxygen free copper, SDI | 
| Application area: | ELA 100 V, Installation, Mobile outdoor / indoor, Studio / Broadcast | 
| Application: | video cable | 
| Colour: | blue | 
| Construction: | 1x02YS(ST)CH0,8/3,7 HD-SDI | 
| Jacket material: | PVC | 
| Jacket Ø [mm]: | 6,00 | 
| Jacket Ø ["]: | 0.2362 | 
| Number of Channels (video): | 1 | 
| Inner conductor: | 1 | 
| Inner conductor (video): | 1 | 
| Inner conductor (video) [mm²]: | 0,50 | 
| Inner conductor (video) [sqin]: | 0.0008 | 
| Inner conductor Ø (video) [mm]: | 0,80 | 
| Inner conductor Ø (video) ["]: | 0.0315 | 
| AWG (video): | 20 | 
| Shielding: | AL / PT-foil + Copper braiding tin-plated 85 % | 
| Shielding factor [%]: | 100 | 
| Copper strands (video): | 1 | 
| Copper strand Ø (video) [mm]: | 0,80 | 
| Copper strand Ø (video) ["]: | 0.0315 | 
| Conductor insulation material: | Gas Injected-PE | 
| Conductor insulation Ø [mm]: | 3,70 | 
| Conductor insulation Ø ["]: | 0.1457 | 
| Weight per 1 m [g]: | 41.42 | 
| Weight at 1000 ft. [lbs]: | 26.9166 | 
| Fire load per m [kWh]: | 0,16 | 
| Style variant: | round | 
| Packing: | 100 m spool | 
| Velocity factor: | 0,82 | 
| Temperature min. [°C]: | -10 | 
| Temperature max. [°C]: | 80 | 
| Max. Transmission length (SMPTE 425M, 3G) (without connectors) [m]: | 121 | 
| Max. Transmission length (SMPTE 425M, 3G) (without connectors) [ft]: | 396.9816 | 
| Max. Transmission length (SMPTE 2081, 6G) (without connectors) [m]: | 82 | 
| Max. Transmission length (SMPTE 2081, 6G) (without connectors) [ft]: | 269.0289 | 
| Max. Transmission length (SMPTE 2082, 12G) (without connectors) [m]: | 51 | 
| Max. Transmission length (SMPTE 2082, 12G) (without connectors) [ft]: | 167,3228 | 
| Width [mm]: | 6 | 
| Width ["]: | 0.2362 | 
| Height [mm]: | 6 | 
| Height ["]: | 0.2362 | 
| Capacity wire/electic screen at 1m (video) [pF]: | 52,9 | 
| Capacity wire/electic screen at 1 ft. (video) [pF]: | 16.1239 | 
| Damping at 200 MHz (100m & 20° C) [dB]: | 11,2 | 
| Damping at 200 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 3.4138 | 
| Damping at 470 MHz (100m & 20° C) [dB]: | 17 | 
| Damping at 470 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 5.1816 | 
| Damping at 862 MHz (100m & 20° C) [dB]: | 24 | 
| Damping at 862 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 7.3152 | 
| Damping at 1000 MHz (100m & 20° C) [dB]: | 26,4 | 
| Damping at 1000 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 8.0467 | 
| Damping at 1485 MHz (100m & 20° C) [dB]: | 32,8 | 
| Damping at 1485 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 9.9974 | 
| Damping at 1750 MHz (100m & 20° C) [dB]: | 35,9 | 
| Damping at 1750 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 10.9423 | 
| Damping at 2150 MHz (100m & 20° C) [dB]: | 40,1 | 
| Damping at 2150 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 12.2225 | 
| Damping at 3000 MHz (100m & 20° C) [dB]: | 47,9 | 
| Damping at 3000 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 14.5999 | 
| Damping at 6000 MHz (100m & 20° C) [dB]: | 77,8 | 
| Damping at 9000 MHz (100m & 20° C) [dB]: | 99,4 | 
| Damping at 12000 MHz (100m & 20° C) [dB]: | 118,6 | 
| Impedance [Ω]: | 75 | 
| Conductor resistance per 1 km [Ω]: | 37 | 
| Conductor resistance per 1000 ft. [Ω]: | 11.2776 | 
| Shield. resistance per 1 km [Ω]: | 20 | 
| Shield. resistance per 1000 ft. [Ω]: | 6.096 | 
| BPVo-Euroclass: | Fca |